即使板式熱交換器在一年內也會出現問題並需要維護, 尤其是它的密封件, 看是否鬆動.
這是內容列表:
- Secondary adjusutment precautions
- Gasket bonding
- Repair and replacement
Secondary adjustment precautions
A 板式熱交換器 is an important component of heat exchange technology in process industry equipment. 各個板式散熱器之間密封的彈性墊片是一種易磨損部件,在自然條件下容易損壞. 如果這些密封件受熱硬化並失去原有的彈性, 熱交換器無法正常運作. The softening of the elastic gasket is related to pressure and temperature, and when the gasket loses its elasticity, the heat exchanger can drip. In some products, in order to solve the drip phenomenon caused by the aging of the gasket, the heat exchanger is allowed to adjust the sealing performance, 那是, tighten the bolts of the combined plate heat exchanger again to adjust the pressure of the elastic gasket between each heat exchanger to solve the drip problem.
Gasket bonding
According to the purpose of gasket use and sealing quality requirements, different manufacturers’ blended sealant and non-blended sealant can be used. Before bonding, it should be thoroughly removed using steam airflow. Residual adhesive and residual gasket on the bonding surface. For blended sealant bonding, residual adhesive and gasket residues on the bonding surface of the plate heat exchanger must be removed by fire. In the case of high-volume bonding, a pool of liquid nitrogen should be prepared to freeze the seals, a heating oven should be prepared to dry the 板式熱交換器 with a gasket at 160°C, and if available, the plate heat exchanger should be chemically cleaned to ensure complete removal of the gasket residue from the bonded parts in the plate heat exchanger bonding surface.
Repair and replacement
Usually, one finds heat exchanger seal failure by dripping during cold movement of the process equipment or during stopping and cooling. Some plate heat exchangers have a secondary adjustment feature that allows the heat exchanger sheet set to be tightened again in the event of a small drip. This increases the stress between the individual gaskets and solves the dripping phenomenon in a short time. In a newly assembled heat exchanger, a larger combination length size can be used, and when dripping occurs, the groups of plate heat exchangers can be tightened again, using a longer combination length size. The maximum combined length size and the minimum combined length size can generally be seen in the nameplate of the heat exchanger. It is important to note that the minimum combination length size cannot be smaller. When the combined heat exchanger reaches the minimum combined length size and still drips, it means that the gasket must be replaced.
These are the maintenance tips for plate heat exchangers, especially regarding the knowledge of flexible gaskets. With the popularity of 熱交換器s, these are no longer just the work of engineers, but skills that each of us needs to master. This way we can greatly reduce the trouble encountered during the use of heat exchangers.